CD60 Techinacal Features | |
Climate type | -25~+55℃ |
Rated voltage | 110~330VAC |
Standard capacitance | 50~1000μF |
Standard capacitance tolerance | 0~+20% |
Loss tangent (tgδ)(20℃,100HZ) | 0.01≤tgδ≤0.15 |
Durability | 55℃,110~165VAC,1s ON,59s OFF,30000 times; |
55℃,220~330VAC,1s ON,59s OFF,15000 times; | |
Constant frrequency: Within ±15% of beginning testing results | |
loss tangent:≤0.20 | |
Between leading – outs | 1.2times working voltage,no breakdown within 2seconds |
Between leading – out and shell | 2000VAC 10seconds,no break down |
Capacity (μf) | 110VAC | 125VAC | 160VAC | 250VAC | 300VAC | |||||
D | H | D | H | D | H | D | H | D | H | |
50 | 34 | 60 | 34 | 60 | 34 | 60 | 34 | 80 | 34 | 80 |
75 | 42 | |||||||||
100 | 80 | 80 | 42 | 45 | 88 | |||||
150 | 80 | 42 | 50 | 95 | 50 | 100 | ||||
200 | ||||||||||
300 | 42 | 42 | 45 | 88 | 100 | 55 | ||||
400 | 45 | 88 | 45 | 88 | 50 | 95 | 55 | 60 | ||
600 | 50 | 95 | 50 | 95 | 60 | 120 | ||||
800 | 100 | 100 | 55 | 100 | ||||||
1000 | 55 | 55 |